HOMA-IR goes back to a 1985 study by Matthews and colleagues. They built a model of how fasting glucose and fasting insulin regulate each other, then compared patients’ fasting values with that model. The resulting estimate correlated closely with the euglycaemic clamp, the reference method used in research (Rs = 0.88). A 2004 review by Wallace and colleagues counted more than 500 publications using HOMA, about 20 times more often to estimate insulin resistance than to estimate beta-cell function.
The short answer: HOMA-IR is a number calculated by multiplying fasting blood glucose (FBS) by fasting insulin and dividing by a constant. The higher it is, the more insulin the body needs to keep blood sugar at the same level, which is the hallmark of insulin resistance. There is still no single cut-off that applies to everyone, so the same number can be read differently depending on the formula used, the laboratory’s insulin assay and the population it is compared with.
This article follows the order in which you meet these questions: which values go in, the formula, research cut-offs abroad and in Thailand, the limitations, and where to get tested.
What Is HOMA-IR and What Is It Calculated From?
HOMA-IR stands for Homeostatic Model Assessment of Insulin Resistance. It is a surrogate marker that needs only one blood sample tested for both glucose and insulin, which is why it is used far more widely than methods requiring repeated blood draws. Before calculating it, it helps to understand what the two values say together.
What Fasting Glucose and Fasting Insulin Show Together
During fasting, blood glucose and insulin regulate each other in a feedback loop, as described in the Matthews model. When glucose rises, the pancreas releases more insulin, and as insulin acts, glucose falls. In someone becoming insulin resistant, cells respond less to insulin, so the pancreas has to release more of it to hold glucose at the same level. A review by Prentki and Nolan (2006) explains that this compensation eventually fails over time. While compensation still works, FBS can look normal even though insulin is higher than it should be, as covered in our article Normal Blood Sugar, High Insulin.
Glucose alone does not show how hard the pancreas is working, and insulin alone does not show how well that insulin controls glucose. HOMA-IR combines the two to answer this question. The reference method, the hyperinsulinemic-euglycemic clamp, requires continuous intravenous insulin and glucose for several hours, so it is mainly used in research. Matthews also reported that the precision of the HOMA estimate is fairly low, with a coefficient of variation of about 31% for insulin resistance. For the basics of the condition, see What Is Insulin Resistance? and Is Insulin Resistance Dangerous?
The HOMA-IR Formula and How to Calculate It from Your Results
The commonly used formula depends on the glucose unit in your report:
- Glucose in mmol/L: HOMA-IR = fasting glucose × fasting insulin (µIU/mL) ÷ 22.5, the formula used in a study of Thai women with PCOS.
- Glucose in mg/dL: HOMA-IR = FBS × fasting insulin (µIU/mL) ÷ 405. The 405 comes from 22.5 × 18, because 1 mmol/L of glucose is about 18 mg/dL.
Both values must come from the same fasting blood draw. If insulin is reported in another unit, such as pmol/L, ask the laboratory how to convert it before using the formula, because the conversion factor can vary by assay.
Reversing the formula shows the insulin level that brings HOMA-IR to a cut-off: insulin = cut-off × 405 ÷ FBS. Using a glucose of 100 mg/dL, the line between normal and prediabetes under American Diabetes Association (ADA) criteria, insulin of about 6.3, 8.1 and 10.1 µIU/mL gives HOMA-IR values of 1.56, 2.0 and 2.5 respectively. All three are research cut-offs discussed in the next sections. This calculation uses guideline thresholds, not anyone’s test results.
Online HOMA-IR Calculators and HOMA2: Why the Numbers Don’t Match
Many people enter their results into an online HOMA-IR calculator and get a number that differs from the one on their lab report. One reason is that HOMA has more than one calculation method. Wallace and colleagues explain that the original 1985 model came with a formula for approximate estimation, the ÷ 22.5 or ÷ 405 formula above. The full model is a computer program, later developed into HOMA2, but it has been used less than the approximation formula.
Results from the two methods are not interchangeable. A study by Mojiminiyi and Abdella (2010) in 226 patients with type 2 diabetes and 319 normoglycemic first-degree relatives defined insulin resistance as the top 25% of the distribution in non-diabetic subjects. The cut-off was 2.5 or above with the original formula (HOMA1) but 1.4 or above with the HOMA2 calculator. The authors concluded that the computational method is a significant determinant of who is classified as insulin resistant. Manley and colleagues (2008) likewise found that the choice of calculator is one of the factors that changes HOMA estimates.
So before comparing your number with any threshold, find out which method produced it and whether the threshold comes from the same method. If your report does not say, ask the laboratory or the doctor who ordered the test.
What Is a Normal HOMA-IR? There Is No Single Cut-off for Everyone
The most common question is what a normal HOMA-IR value is. MDCalc, a widely used medical calculator, states that there is no universally accepted single cut-off and no validated management algorithms or guidelines that use this score. The table below lists cut-offs that have a named source, together with the population each one comes from.
| HOMA-IR cut-off | Source | Population / context |
|---|---|---|
| 2.0–3.0 | MDCalc | Commonly used in US clinical and research settings |
| ≥ 2.5 | MDCalc (NHANES) | US adults |
| 1.4–2.5 | MDCalc | Asian populations, for metabolic syndrome and dysglycemia |
| Men ≥ 1.56 · women ≥ 1.64 | Do et al. (2010) | Hospital staff in Bangkok aged 35 and over |
| > 2.0 | Wongwananuruk et al. (2012) | Thai women of reproductive age with PCOS, screening for glucose intolerance |
Cut-offs Used in the United States and Asian Populations
In the United States, MDCalc notes that values between 2.0 and 3.0 are commonly used in clinical and research settings, while the national NHANES survey uses 2.5 or above to indicate insulin resistance. NHANES III data in adults without diabetes showed a median of 2.2 and a mean of 2.8.
Cut-offs in Asian populations tend to be lower. MDCalc states that cut-offs for metabolic syndrome and dysglycemia in Asian populations typically range from 1.4 to 2.5. Applying the US threshold of 2.5 to Thai adults could mean overlooking values between 1.5 and 2.4, even though some Asian studies already treat them as worth attention.
Research in Thai Adults
Do and colleagues (2010) studied 1,217 staff members of King Chulalongkorn Memorial Hospital aged 35 and over, without diabetes, who attended annual health check-ups in 2008. The researchers used the 90th percentile of normal-weight subjects with normal fasting glucose as the cut-off, giving 1.56 for men and 1.64 for women. With these thresholds, 25.1% of men and 21.5% of women were classified as insulin resistant. The authors noted that because the sample consisted of hospital personnel, the results may not apply to the general Thai population.
A second study, by Wongwananuruk and colleagues (2012), looked at 250 women with polycystic ovary syndrome (PCOS) at Siriraj Hospital, with a mean age of 25.4 years. It found that HOMA-IR above 2.0 could be used to screen for glucose intolerance (area under the ROC curve 0.82), and concluded that a positive screen should be followed by a more specific test to confirm the diagnosis. For more on insulin resistance in PCOS, see Insulin Resistance and PCOS.
The two studies answer different questions. The first shows which values are higher than in most normal-weight people, and the second shows which value helps screen for glucose intolerance in people with PCOS. Which threshold applies depends on the question the doctor is using the number to answer.
Limitations of HOMA-IR to Know Before Reading Your Result
HOMA-IR is easy to calculate and needs only one blood sample, but studies that examined it directly point to several limitations:
- Insulin values vary by assay: Manley and colleagues (2008) measured insulin in the same samples with 11 different assays and found that HOMA estimates varied by up to twofold depending on the assay. The authors stated that HOMA is hard to apply to individual patient care while insulin results from different laboratories still disagree, and recommended assays traceable to a single insulin reference method.
- There is no standard insulin assay: the KOGES study of 7,643 Korean adults aged 40–69 named this as a significant drawback of HOMA-IR, and found that in that cohort the TyG index, calculated from triglycerides and glucose, predicted diabetes better.
- Insulin is released in pulses: the original model used three blood samples taken 5 minutes apart to account for pulsatility, although large studies later used a single sample. A single-draw value therefore carries some built-in variation.
- Better suited to groups than individuals: Wallace and colleagues advise that HOMA is appropriate for cohort and epidemiological studies, that the input data must be robust, and that results must be interpreted carefully.
These limitations do not make HOMA-IR useless. They mean the number is best read as a screening signal rather than a verdict, and that results from different laboratories should be compared with caution.
Where to Test HOMA-IR, and What to Do If It Is High
HOMA-IR requires an insulin test on top of glucose, so it is often not part of a basic health check-up. At Chula Doctor Wellness, it is one of the 9 markers in the Heart Disease Marker program, alongside LDL-C, HDL-C, triglycerides, small dense LDL, ApoB, ApoA-I, lipoprotein(a) and hs-CRP. The program page lists the preparation: no food or drinks for 8–12 hours before the test (plain water is allowed), no alcohol or high-fat food for at least 24 hours, no strenuous exercise for about 24 hours, and tell the team about any medicines, vitamins or supplements you take without stopping medicines on your own.
On price, the program page says fees may vary with monthly promotions, so ask the clinic directly by phone or LINE for current prices, branches and appointment times.
When HOMA-IR is above the cut-off your doctor uses, the next step is testing with clear diagnostic criteria. Under ADA criteria, a fasting glucose of 100–125 mg/dL or an HbA1c of 5.7–6.4% indicates prediabetes, and 126 mg/dL or 6.5% and above meets the criteria for diabetes. The doctor may also order an oral glucose tolerance test (OGTT). The doctor then reviews all results together with your age, existing conditions, medicines and family history before planning care that suits you.
Summary
HOMA-IR is calculated from fasting glucose and fasting insulin taken in the same blood sample, and shows how much insulin the body needs to keep blood sugar at the same level. The usual formula is FBS (mg/dL) × insulin ÷ 405, but there is still no single cut-off for everyone. Research in Thai adults used 1.56 for men and 1.64 for women, lower than the range commonly used in the United States, and the result also depends on the calculation method and on each laboratory’s insulin assay.
That makes HOMA-IR a screening tool that tells you when to test in more detail. Diagnosing prediabetes or diabetes still relies on FBS, HbA1c or OGTT under ADA criteria, together with a doctor’s assessment.
Results of testing and care vary from person to person. The numbers in this article are for understanding only and should not be used to diagnose yourself or adjust medicines. If your HOMA-IR or other blood results concern you, discuss them with a doctor for advice that fits your situation.









